Fastforward
 
 
 
Fastforward's stats
 
Reviews
  • Review count
    0
  • Helpfulness votes
    0
  • First review
    None
  • Last review
    None
  • Featured reviews
    0
  • Average rating
    0
 
Reviews comments
  • Review comment count
    0
  • Helpfulness votes
    0
  • First review comment
    None
  • Last review comment
    None
  • Featured review comments
    0
 
  • Question count
    1
  • Helpfulness votes
    0
  • First question
    January 19, 2013
  • Last question
    January 19, 2013
  • Featured questions
    0
 
Answers
  • Answer count
    0
  • Helpfulness votes
    0
  • First answer
    None
  • Last answer
    None
  • Featured answers
    0
  • Best answers
    0
 
Stories
  • Story count
    0
  • Helpfulness votes
    0
  • First story
    None
  • Last story
    None
  • Featured stories
    0
 
Stories comments
  • Story comment count
    0
  • Helpfulness votes
    0
  • First story comment
    None
  • Last story comment
    None
  • Featured story comments
    0
 
Answers
  • Answer count
    0
  • Helpfulness votes
    0
  • First
    None
  • Last
    None
  • Featured
    0
 
 
Fastforward's Reviews
 
Fastforward has not submitted any reviews.
 
Fastforward's Review Comments
 
Fastforward has not submitted comments on any reviews.
 
Fastforward's Questions
 
Service and Troubleshooting Guide. Diagnosis, disassmbly, and repair instuctions specific to brushless 15kW standby generators. 15kW Models included 040203, 040210, 040213, 040234, 040235, 040236, 040240, 040250, 040256, 040259, 040261, 040262, 040263, 040264, 040274, 040275, 040284, 040285, 040303, 040303A, 040308, 040308GEC NOTE: a licensed electrician or plumber is/may be required to perform some repairs
 

Generator engine stumbling or missing

I had a 15KW Milbank (B&S) generator Model 040274A installed by a contractor in late December 2012. When it runs under load or during its weekly run, it sound like it is stumbling or missing. The generator fuel line is directly off the meter outlet (outside) and 8 feet underground from the meter (1.5 inches in diameter) and reduced to 3/4 inches for the gas valve, sediment trap and into the flexible fuel hose at the generator with three 90 degreee turns. See pipture. The gas meter is rated at 400/308 CFH at 1/2 inch WC. Downstream from the meter on a different gas leg is a gas hot water heater and furnace both with 1/2 gas lines. The contractor listen to the generator and says that this is how all of them sound that he has installed. Is this normal?
User submitted photo
4 months, 4 weeks ago
Customer avatar
by
Fastforward
NY
 